Efficiency improvement of single-phase asymmetric multilevel inverters

Md. Kamrul Islam, Leshunus Sidq, Kazi Mahtab Kadir, Tapan Kumar Chakraborty

Abstract


This study evaluates the efficiency and harmonic performance of single-phase asymmetric cascaded multilevel inverters that use binary (1:2) DC source ratios to raise the output voltage-level count while reducing component count. Switching, conduction, harmonic, and control-circuit losses are quantified separately using datasheet parameters of a commercial IGBT (TO-247, 600 V, 40 A) at a power factor of 0.95. The sinusoidal switching angle technique (θ = sin⁻¹(Vo/Vm)) is evaluated at all levels, both with and without LC filtering. The 7-level design attains 74.79% efficiency with 8 switches, but the 11-level configuration achieves 74.96% efficiency with 12 switches. Total harmonic distortion (THD) decreases from 37.28% to 10.77% as levels rise with filtering. The 5-level design offers the best cost-to-performance balance, whereas the 7 and 11-level designs give the strongest efficiency gain per added switch.

Keywords


asymmetrical multilevel inverter; cascaded H-bridge; efficiency; sinusoidal switching angle; THD reduction

Full Text:

PDF


DOI: http://doi.org/10.11591/ijpeds.v17.i4.pp2734-2744

Refbacks

  • There are currently no refbacks.


Copyright (c) 2026 Md. Kamrul Islam, Leshunus Sidq, Kazi Mahtab Kadir, Tapan Kumar Chakraborty

Creative Commons License